DATA E-COOLER

Water system

The Data E-Cooler is an innovative liquid cooler, specifically designed for data centres.

A 100% French, eco-efficient, tailor-made solution for critical infrastructure.

This range addresses the challenges of decarbonisation and the ecological transition, while guaranteeing optimum performance: reliability, energy efficiency and respect for the environment, thanks to the use of propane (R290), a natural refrigerant with an almost zero GWP (0.02).

Designed to adapt to your technical constraints:

  • Dimensions
  • Acoustics
  • Water operating conditions

The Data E-Cooler incorporates advanced technologies to maximise energy efficiency and minimise its carbon footprint.

Description

Energy and environmental performance

  • One of the lowest pPUE values on the market, thanks to free chilling mode. Dry or wet operation.
  • Full heat recovery for use in district heating networks, eco-districts or healthcare facilities
  • Reduced WUE
  • Compatible with all cooling terminals: CRAH, Fan Wall, DLC, immersion, etc.

Performance range (depending on configuration):

  • Cooling capacity: from 250 kW to 1.5 MW
  • Water operating conditions: from 18°C to 35°C (30% MEG glycol loop)
  • Outdoor temperatures: up to +48°C
  • Sound level: from 62 to 79 dB(A) at 15 metres

A robust and innovative design for maximum reliability.

  • Modular, multi-circuit design for optimum redundancy
  • Screw compressors
  •  Ø910 axial fans: EC electronically commutated motors for optimum efficiency and low noise levels
  • High-performance heat exchangers: evaporator/condenser with brazed plate heat exchangers (BPHE)
  • Integrated adiabatic cooler
  • Next-generation controller: intelligent management of switching between free cooling and chiller mode.
  • Machine-to-machine communication
  • IP54 electrical cabinet

Products top benefits

  • Propane refrigerant (R290) – GWP 0.02 – compliant with F-Gas III regulations
  • Heat recovery for energy valorisation
  • Free cooling optimised to reduce electricity consumption
  • One of the lowest pPUE values on the market
  • Low water consumption, reduced WUE and no chemical treatment
  • Modular redundancy for maximum availability
  • Adaptation to dimensional and acoustic constraints
  • Bespoke study to optimise payback period / ROI
  • Compatibility with all cooling terminals (CRAH, Fan Wall, DLC, immersion)

Product options

Frame – Casing

  • Compartmentalised technical section to reduce noise nuisance.
  • Enhanced protection for corrosive environments (coastal locations).

Thermodynamics

  • Total heat recovery
  • Hydraulic kit for simplified installation

Acoustics

  • Optimised acoustic performance

Electrical

  • Propane detector for enhanced safety
  • ATEX fans

Installation

  • Anti-vibration mounts to limit vibration transmission.

Warranty

  • 1 year parts and labour (standard)
  • 20-year anti-corrosion warranty on the aluminium structure

Associated services

  • Preventive and corrective maintenance by certified technicians
  • Dedicated helpline
  • Nearby technicians
  • Energy Performance unit to optimise operating costs