CINEFFI R32

Air handling Heat pump 4-damper system

Compliant with the ErP 2021 directive, the CINEFFI R32 is a double-flow heat pump specially designed for ventilating, heating and air-conditioning rooms with variable occupancy, such as cinemas. These double-flow heat pumps incorporate a range of equipment to optimise energy use.

The CINEFFI R32 is a rooftop unit using R32, a low GWP fluid.

Description

The CINEFFI R32 air handling system is a high-efficiency, 4-damper double flow heat pump using R32 fluid (low GWP) for heating, free cooling and air conditioning cinemas. CINEFFI R32 is a low noise unit specially designed for cinema facilities. ErP 2021 compliant, the CINEFFI R32 meets European regulatory obligations under the ErP (Energy related Products) 2009/125/EC Eco-design Directive.

 Thanks to its full aluminium structure (frame & casing) that ensures an excellent corrosion protection, this air conditioning and heating system is covered by a 20-year guarantee against corrosion (frame and casing).

This single flow rooftop heat pump is delivered ready to operate. A separate technical compartment facilitates unit control and maintenance and allows measurement and adjustment during operation.

The CINEFFI R32 provides precise regulation, adapting the rotational speeds of the power stages, for optimum, continuous energy performance throughout its years of operation.

This rooftop comes with a 5-year basic warranty and all ETT services: Commissioning, Audits, Service contracts etc.

Products top benefits

  • R32 refrigerant (Low GWP)
  • ERP 2021
  • 168 Air flow configurations
  • Recovery of extracted air

Product options

Frame – Casing

  • Motorised external supply air damper (CH38 – 2006/42/EC Directive)

Air handling

  • Operation with all recirculated air (excluding Public Buildings)
  • All fresh air operation
  • Actuating smoke detector with battery back-up
  • Epoxy coating on supply air fans
  • Analogue air flow controller (AFC) with auto-adjustment of supply fans flow rate
  • Pressure gauges for supply air filters
  • ISO Coarse 65% (G4) refillable 98mm supply filters with analogue sensor
  • ISO ePM10 50% (M5) 98mm supply filters with analogue sensor
  •  Double filters ISO Coarse 65% (G4) + ISO ePM1 50% (F7) or ISO ePM1 80% (F9) (48 + 48mm) at supply with analogue sensor
  •  ISO ePM1 50% (F7) 98mm supply filters with analogue sensor
  • ISO ePM1 80% (F9) 98mm supply filters with analogue sensor
  • Pressure relief vent
  • Cowl for pressure relief gravity damper
  • Defrosting damper
  • Fresh air cowl extension

Thermodynamics

  • Compressor MAP monitoring
  • Vinyl coating on thermodynamic coils
  • Diagnostic assistance for refrigerant leaks detection
  • HP and LP pressure gauges

Auxiliaries

  • Auxiliary hot water coil with analogue frost protection thermostat
  • Modulating 3-way valve for hot water coil
  • Shut-off valve on the supply + ‘TA’ regulating valve on the return for hot water coil
  • 2-stage sequential electric heaters + load shedding via dry contact
  • Preheating of fresh air by 3-stage electric auxiliary heaters

Electrics

  • Totalising electrical energy metering in compliance with RT 2012
  • Aluminium/copper terminal block (mandatory for aluminium supply cables)
  • 230V/16 A single-phase PC socket in the technical room (separate power supply to be provided by the installer)
  • IT earthing system compatibility
  • Cable cover for external power supply (to be fitted by the installer)

Installation

  • Adjustable connecting aluminium roof curb
  • Aluminum connection adapter curb
  • Adjustable ventilated aluminium curb
  • Ventilated adapting aluminium curb
  • 200, 400 or 600 mm aluminium feet